Show simple document record

Other titre : Résistance des murs de cisaillement renforcés de PRFV

dc.contributor.advisorBenmokrane, Brahimfr
dc.contributor.authorMohamed, Nayera Ahmed Abdel-Raheemfr
dc.date.accessioned2015-02-23T18:18:42Z
dc.date.available2015-02-23T18:18:42Z
dc.date.created2013fr
dc.date.issued2013fr
dc.identifier.urihttp://hdl.handle.net/11143/6136
dc.description.abstractWith the rise in constructing using FRP reinforcement, owing to corrosion problems in steel-reinforced structures, there is a need for a system to resist lateral loads induced from wind and earthquake loads. The present study addressed the applicability of reinforced-concrete shear walls totally reinforced with glass-fiber-reinforced polymer (GFRP) bars to attain reasonable strength and drift requirements as specified in different codes. Four large-scale shear walls - one reinforced with steel bars (as reference specimen) and three totally reinforced with GFRP bars - were constructed and tested to failure under quasi-static reversed cyclic lateral loading. The GFRP-reinforced walls had different aspect ratios covering the range of medium-rise walls. The reported test results clearly showed that properly designed and detailed GFRPreinforced walls could reach their flexural capacities with no strength degradation, and that shear, sliding shear, and anchorage failures were not major problems and could be effectively controlled. The results also showed recoverable and self-centering behavior up to allowable drift limits before moderate damage occurred and achieved a maximum drift meeting the limitation of most building codes. Acceptable levels of energy dissipation accompanied by relatively small residual forces, compared to the steel-reinforced shear wall, were observed. Finite element simulation was conducted and the analyses captured the main features of behavior. Interaction of flexural and shear deformations of the tested shear walls was investigated. It was found that relying on the diagonal transducers tended to overestimate shear distortions by 30% to 50%. Correcting the results based on the use of vertical transducers was assessed and found to produce consistent results. Decoupling the flexural and shear deformations was discussed. Using GFRP bars as elastic material gave uniform distribution of shear strains along the shear region, resulting in shear deformation ranging from 15 to 20% of total deformation. The yielding of the steel bars intensified the shear strains at the yielding location, causing significant degradation in shear deformation ranging from 2 to 40% of total deformation. The results obtained demonstrated significantly high utilization levels of such shear wall type, therefore, primary guidelines for seismic design of GFRP-reinforced shear wall in moderate earthquakes regions was presented, as no design guidelines for lateral load resistance for GFRP-reinforced walls are available in codes. The ultimate limit state was addressed by providing strength capacity that limit ductility demand to their safe flexural displacement capacity. The strength demands were derived from ground motion spectra using modification factors that depend on both the strength and energy absorption of the structure. Deformation capacity was derived by proposing new definitions for elastic (virtual yield) displacement and maximum allowable displacement. Strength modification factor was proposed based on the test results. The occurrence of "virtual plastic hinge" for GFRP-reinforced shear walls was described providing new definitions convenient with the behavior of the GFRP-reinforced shear walls. "Virtual plastic hinge" length was estimated based on observations and calculations. Subsequently, the experimental results were used to justify the proposed design procedure. The promising results could provide impetus for constructing shear walls reinforced with GFRP bars and constitute a step toward using GFRP reinforcement in such lateral-resisting systems.fr
dc.language.isoengfr
dc.publisherUniversité de Sherbrookefr
dc.rights© Nayera Ahmed Abdel-Raheem Mohamedfr
dc.subjectDuctility indexfr
dc.subjectDrift capacityfr
dc.subjectDesignfr
dc.subjectFinite elementfr
dc.subjectEnergy dissipationfr
dc.subjectDeformationfr
dc.subjectShear wallsfr
dc.subjectHysteretic behaviorfr
dc.subjectCyclic loadsfr
dc.subjectConcrete, GFRP barsfr
dc.titleStrength and drift capacity of GFRP-reinforced concrete shear wallsfr
dc.title.alternativeRésistance des murs de cisaillement renforcés de PRFVfr
dc.typeThèsefr
tme.degree.disciplineGénie civilfr
tme.degree.grantorFaculté de géniefr
tme.degree.levelDoctoratfr
tme.degree.namePh.D.fr


Files in this document

Thumbnail

This document appears in the following Collection(s)

Show simple document record