dc.description.abstractThe response of concentrated photovoltaic (CPV) structures under wind loading has to be carefully predicted to optimize the design of these structures. Designers normally rely on wind tunnel tests and equivalent static approaches as recommended by codes for the design of this type of nonconventional structures. This paper aims to evaluate the full scale wind response of a concentrated photovoltaic (CPV) prototype with mirror surface of 8 ∗ 16 m2 and correlate it with wind measurements made near the solar structure. The full-scale wind response of the structure was evaluated with continuous 10 min measurements of deformations on tower leg members during moderate wind events. The utility of this work derives from enriching field measurement data in order to understand the behavior of this type of structure and to validate the previous wind tunnel testing works. Standard wind design process based on the analytical method, which is adopted by ASCE 7, is also revisited in the light of the full scale observations.fr
dc.language.isoengfr
dc.relation.isversionofhttps://doi.org/10.1016/j.solener.2017.03.010fr
dc.rightsAttribution - Pas d’Utilisation Commerciale - Pas de Modification 2.5 Canada*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/ca/*
dc.subjectParabolic solar concentratorfr
dc.subjectFull scale measurementfr
dc.subjectWind force coefficientsfr
dc.subjectEquivalent static wind loadfr
dc.subjectGust effect factorfr
dc.titleFull-scale measurement of the response of a CPV tracker structure prototype under wind loadfr
dc.typeArticlefr
udes.description.typestatusPrépublicationfr
udes.description.typepubScientifiquefr
udes.description.diffusionDiffusé par Savoirs UdeS, le dépôt institutionnel de l'Université de Sherbrookefr
dc.identifier.bibliographicCitationKaabia, B., Langlois, S., Légeron, F. (2017). Full-scale measurement of the response of a CPV tracker structure prototype under wind load. Manuscrit soumis pour publication. https://doi.org/10.1016/j.solener.2017.03.010fr
udes.autorisation.depottruefr
udes.description.ordreauteursKaabia, Bassem; Langlois, Sébastien; Légeron, Frédéricfr


Files in this document

Thumbnail
Thumbnail

This document appears in the following Collection(s)

Show simple document record

Attribution - Pas d’Utilisation Commerciale - Pas de Modification 2.5 Canada
Except where otherwise noted, this document's license is described as Attribution - Pas d’Utilisation Commerciale - Pas de Modification 2.5 Canada